Overview

Monitor biomass and growth rates in your bioreactors with high-resolution growth curves using the CGQ BioR. Optical biomass measurements are based on backscattered light detection without the use of invasive sensors. Simply mount the sensor plate to the outside of your reactor and monitor the biomass through the vessel wall. Follow the growth of your cultures in real-time to gain actionable insights into your strain’s growth behavior.

  • Save time with automated, online, non-invasive biomass monitoring in several bioreactors in parallel
  • Two measurement modes for high and low biomass concentrations
  • No cleaning or sterilization required
  • Free up reactor port space
  • Flexible integration of biomass data into other software (e.g., analog, OPC…)
  • Gain actionable insights with high resolution growth curves
  • Powerful DOTS Software for easy sensor handling and real-time data visualization

 

What Our Customers Are Saying

"The automated CGQ BioR system provides precise growth curves with a very dense sampling interval, freeing my time for tasks with higher added value.”

-Dipl. Ing. Andreas Hoffmann (TU Dresden)
TU Dresden
"By using CGQ BioR, all we need to do is attach the sensor on the reactor, start the fermentation, and monitor the whole fungal growth online without the need to take samples for dry weight. Furthermore, since the sensor is attached on the wall of the bioreactor, it does not give additional shear stress to the fungi that could eventually affect the fungal growth."

-Winda Soerjawinata (Hochschule Trier)
Soerjawinata-Interview-post (1)

How It Works

The BioR’s technique for non-invasive cell density monitoring is based on the principle of light backscattering.

Using LEDs and photodiodes, the BioR sensor emits light through the wall of the vessel and measures the amount of light that is scattered back to the photodiode, resulting in a higher measured intensity. The more cells that are in the medium, the more light is scattered back. This backscatter signal can be correlated with offline cell density data, such as OD600 or cell dry weight (CDW).

CGQ BioR Sensing
Architecture

BioR Sensing  Architecture

The sensor of the CGQ BioR contains two LEDs with different wavelengths and a photodiode. Choosing between two LEDs allows selecting the optimal wavelength for precise measurements at both, low and high cell densities.

Biomass Monitoring by Backscattered Light

Biomass Monitoring by Backscattered Light

Light is emitted from the LEDs into the culture medium. While most photons go straight through the broth, some are scattered back by the cells and return to the photodiode, which measures the scattered light intensity. The higher the cell density, the more light is scattered back to the photodiode.

Application Data & Results

Explore applications in real-world situations. Looking for something specific? Contact us to see data for your organism and application.

Growth-Curves-Sulfolobus-acidocaldarius

Sulfolobus acidocaldarius, 3L bioreactor, 75 °C, 400 hours

Works With Unique Organisms (Thermophilic, Filamentous, Anaerobic, and More)

Backscattered light readings with the CGQ BioR provide reliable data even under severe conditions, and correlates well with Cell Dry Weight (CDW) and OD600. Read the case study →

Want to see data for your organism or application?

We have tested over 100 microorganisms for more than 50 different applications with our technology.

Speak With An Expert

Hardware & Software Components

BioR Sensor

BioR Sensor

Each sensor is positioned outside of the bioreactor, measuring the biomass through the vessel wall.

BioR Hub

Hub

Several sensors can be connected to a single hub. The BioR hub bundles the data from all monitored bioreactors and sends it to the DOTS Software.

DOTS Software

SBI-Icon-dots-software-computer-2

The DOTS Software receives the data from the hub and visualizes backscattered light intensities in real-time, providing high-resolution growth curves. 

From Estimation to Information

Why CGQ BioR for your Bioreactors?

Manual sampling-based data is often not sufficient to fully understand the bioprocess. Offline sampling is cumbersome and time-consuming, resulting in lower measurement frequency with most pulls being at the start or the end of the experiment. This means that critical information from your growth phases are being overlooked which could have a detrimental impact on your final product. Automated online measurements, on the other hand, never miss a moment. With high-resolution, real-time growth curves, you can detect bioprocess changes on the spot.

Cell Growth Quantifier for Bioreactors (CGQ BioR)
Cell Growth Quantifier for Bioreactors (CGQ BioR)

Specifications

Compatible Laboratory Infrastructure

The CGQ BioR is compatible with a variety of bioreactors. Different sized attachment straps provide maximum flexibility, allowing the same sensor to be used with different bioreactor sizes and manufacturers.

For different reactor types:

  • Single-jacket
  • Double-jacket

For different reactor sizes:

  • Mini bioreactor systems
  • Benchtop bioreactors
  • Production scale

Compatible Organisms

While application requirements can vary, the CGQ BioR has proven successful in monitoring biomass for many different types of cultures, including:

Bacteria

  • Escherichia coli
  • Corynebacterium glutamicum
  • Bacillus subtilis
  • Pseudomonas putida
  • Pseudomonas taiwanensis
  • Gluconobacter oxydans
  • Lactobacillus plantarum
  • Vibrio natriegens
  • Vibrio cholerae
  • Staphylococcus aureus
  • Klebsiella pneumoniae
  • Actinobacillus pleuropneumoniae
  • Chromobacterium violaceum
  • Blautia producta
  • Hungtatella hathewayi
  • Prevotella copri

Yeast

  • Saccharomyces cerevisiae
  • Schizosaccharomyces pombe
  • Pichia pastoris
  • Yarrowia lipolytica
  • Kluyveromyces lactis
  • Hansenula polymorpha
  • Ustilago maydis

Filamentous organisms

  • Aspergillus fumigatus
  • Aspergillus nidulans
  • Aspergillus niger
  • Streptomyces acidiscabies
  • Streptomyces venezuelae
  • Trichoderma reesei

Archaea

  • Haloferax volcanii

  • Sulfolobus acidocaldarius

Anaerobic organisms

  • Acetobacterium woodii

  • Clostridium aectobutylicum

  • Clostridium ljungdahlii

  • Clostridium difficile

Phototrophic organisms

  • Chlorella vulgaris

  • Scenedesmus obliquus

  • Synechococcus elongatus

  • Nicotiana tabacum BY-2 (plant cells)

Which vessels can I attach the BioR to?

The BioR can be easily strapped onto a wide range of vessel types. The only requirement is that it is either a see-through material (glass, see-through plastic) or - for stainless steel - that it has a transparent window of at least 2 × 2 cm located at the height of the culture broth, allowing the sensor housing to attach securely and optically monitor the fermentation broth. In addition to standard vessels, the BioR is also compatible with various photobioreactors. 

Below, you’ll find a non-exhaustive list of bioreactors that are compatible with the BioR, as well as a list of vessel types that are not suitable. If you are unsure whether your vessel can be used with the BioR, our support team will be happy to assist you.

Bioreactors/vessels that the BioR does work with:

  • Infors HT Benchtop Bioreactor Minifors 2
  • Infors HT Benchtop Bioreactor Multifors 2
  • Infors HT Benchtop Bioreactor Labfors 5
  • Sartorius Univessel® Glass Benchtop Bioreactors of all sizes
  • Sartorius Univessel® SU Bioreactors of all sizes
  • Sartorius Ambr® 250 Modular System
  • eppendorf SciVario® twin Benchtop Bioreactors for Microbiology
  • eppendorf BioFlo® 120 Bioreactors
  • eppendorf BioFlo® 320-Bioreaktoren
  • eppendorf BioBLU® c Single-Use Bioreactors 1c, 3c, 10c, 50c
  • eppendorf BioBLU® f Single-Use Bioreactors 1f, 3f, 10f, 50f
  • eppendorf DASGIP® Bioblock/SciVario® twin Stirrer Vessels for microbial applications
  • IKA Habitat all sizes
  • IKA photobioreactor Algaemaster

 

Bioreactors/vessels that the BioR does not work with:

  • Infors HT Benchtop Bioreactor Techfors
  • Infors HT Benchtop Bioreactor Techfors S
  • eppendorf BioBLU® c Single-Use Bioreactors 0.3c
  • eppendorf BioBLU® f Single-Use Bioreactors 0.3f
Can I use the BioR when I use a heating/water jacket on my bioreactor?

It depends on the design of your heating jacket. If the jacket completely encloses the bioreactor, the CGQ BioR cannot be used. However, many heating jackets do not cover the entire length of the vessel and leave a gap. As long as this gap is at least 2 × 2 cm and the BioR can be mounted directly onto the window without any distance in between, measurements will work reliably.

Please also note that the sensor’s standard operating temperature is up to 45°C. Significantly higher temperatures caused by the heating jacket may damage the sensor.

Can I integrate the data into the software that I am using or do I need to buy the DOTS Software as well?

The BioR allows flexible integration of biomass data into other software platforms (e.g., via analog output or OPC). It can be seamlessly added to your existing infrastructure, including the bioreactor software you already use, without requiring the DOTS Software. Additionally, the DOTS Software is able to create a continuous csv export of the data created, allowing further integration options.

Does the BioR require a port space?

No. Unlike invasive probes that occupy port space, the BioR is completely non-invasive and operates without using or blocking any ports.

What is the difference between high and low biomass modes?

The two modes differ in sensitivity and wavelength. Low biomass mode is optimized for low OD ranges (OD₆₀₀ 0.5–50) and uses a wavelength of 521 nm, while high biomass mode is designed for higher OD ranges (OD₆₀₀ 5–200) and operates at 940 nm. You will need to select the appropriate mode before starting your run, as it is not possible to switch modes once the experiment has begun.

Does the BioR need to be calibrated?

No. The BioR can be strapped onto your vessel and will immediately begin monitoring biomass in arbitrary units (a.u.) — no calibration required.

Does the gassing rate or stirring speed influence my readings?

As an optical sensor, the CGQ BioR measures all optically active particles, including air bubbles in the bioreactor. Consequently, changing conditions—such as when running the reactor in cascadic mode—may interfere with biomass readings. This can often be minimized by adjusting the sensor position. For best results, keep the aeration rate and stirring speed as constant as possible.

Compatibility

Compatible Laboratory Infrastructure

The CGQ BioR is compatible with a variety of bioreactors. Different sized attachment straps provide maximum flexibility, allowing the same sensor to be used with different bioreactor sizes and manufacturers.

For different reactor types:

  • Single-jacket
  • Double-jacket

For different reactor sizes:

  • Mini bioreactor systems
  • Benchtop bioreactors
  • Production scale
Organisms

Compatible Organisms

While application requirements can vary, the CGQ BioR has proven successful in monitoring biomass for many different types of cultures, including:

Bacteria

  • Escherichia coli
  • Corynebacterium glutamicum
  • Bacillus subtilis
  • Pseudomonas putida
  • Pseudomonas taiwanensis
  • Gluconobacter oxydans
  • Lactobacillus plantarum
  • Vibrio natriegens
  • Vibrio cholerae
  • Staphylococcus aureus
  • Klebsiella pneumoniae
  • Actinobacillus pleuropneumoniae
  • Chromobacterium violaceum
  • Blautia producta
  • Hungtatella hathewayi
  • Prevotella copri

Yeast

  • Saccharomyces cerevisiae
  • Schizosaccharomyces pombe
  • Pichia pastoris
  • Yarrowia lipolytica
  • Kluyveromyces lactis
  • Hansenula polymorpha
  • Ustilago maydis

Filamentous organisms

  • Aspergillus fumigatus
  • Aspergillus nidulans
  • Aspergillus niger
  • Streptomyces acidiscabies
  • Streptomyces venezuelae
  • Trichoderma reesei

Archaea

  • Haloferax volcanii

  • Sulfolobus acidocaldarius

Anaerobic organisms

  • Acetobacterium woodii

  • Clostridium aectobutylicum

  • Clostridium ljungdahlii

  • Clostridium difficile

Phototrophic organisms

  • Chlorella vulgaris

  • Scenedesmus obliquus

  • Synechococcus elongatus

  • Nicotiana tabacum BY-2 (plant cells)

Resources
FAQs
Which vessels can I attach the BioR to?

The BioR can be easily strapped onto a wide range of vessel types. The only requirement is that it is either a see-through material (glass, see-through plastic) or - for stainless steel - that it has a transparent window of at least 2 × 2 cm located at the height of the culture broth, allowing the sensor housing to attach securely and optically monitor the fermentation broth. In addition to standard vessels, the BioR is also compatible with various photobioreactors. 

Below, you’ll find a non-exhaustive list of bioreactors that are compatible with the BioR, as well as a list of vessel types that are not suitable. If you are unsure whether your vessel can be used with the BioR, our support team will be happy to assist you.

Bioreactors/vessels that the BioR does work with:

  • Infors HT Benchtop Bioreactor Minifors 2
  • Infors HT Benchtop Bioreactor Multifors 2
  • Infors HT Benchtop Bioreactor Labfors 5
  • Sartorius Univessel® Glass Benchtop Bioreactors of all sizes
  • Sartorius Univessel® SU Bioreactors of all sizes
  • Sartorius Ambr® 250 Modular System
  • eppendorf SciVario® twin Benchtop Bioreactors for Microbiology
  • eppendorf BioFlo® 120 Bioreactors
  • eppendorf BioFlo® 320-Bioreaktoren
  • eppendorf BioBLU® c Single-Use Bioreactors 1c, 3c, 10c, 50c
  • eppendorf BioBLU® f Single-Use Bioreactors 1f, 3f, 10f, 50f
  • eppendorf DASGIP® Bioblock/SciVario® twin Stirrer Vessels for microbial applications
  • IKA Habitat all sizes
  • IKA photobioreactor Algaemaster

 

Bioreactors/vessels that the BioR does not work with:

  • Infors HT Benchtop Bioreactor Techfors
  • Infors HT Benchtop Bioreactor Techfors S
  • eppendorf BioBLU® c Single-Use Bioreactors 0.3c
  • eppendorf BioBLU® f Single-Use Bioreactors 0.3f
Can I use the BioR when I use a heating/water jacket on my bioreactor?

It depends on the design of your heating jacket. If the jacket completely encloses the bioreactor, the CGQ BioR cannot be used. However, many heating jackets do not cover the entire length of the vessel and leave a gap. As long as this gap is at least 2 × 2 cm and the BioR can be mounted directly onto the window without any distance in between, measurements will work reliably.

Please also note that the sensor’s standard operating temperature is up to 45°C. Significantly higher temperatures caused by the heating jacket may damage the sensor.

Can I integrate the data into the software that I am using or do I need to buy the DOTS Software as well?

The BioR allows flexible integration of biomass data into other software platforms (e.g., via analog output or OPC). It can be seamlessly added to your existing infrastructure, including the bioreactor software you already use, without requiring the DOTS Software. Additionally, the DOTS Software is able to create a continuous csv export of the data created, allowing further integration options.

Does the BioR require a port space?

No. Unlike invasive probes that occupy port space, the BioR is completely non-invasive and operates without using or blocking any ports.

What is the difference between high and low biomass modes?

The two modes differ in sensitivity and wavelength. Low biomass mode is optimized for low OD ranges (OD₆₀₀ 0.5–50) and uses a wavelength of 521 nm, while high biomass mode is designed for higher OD ranges (OD₆₀₀ 5–200) and operates at 940 nm. You will need to select the appropriate mode before starting your run, as it is not possible to switch modes once the experiment has begun.

Does the BioR need to be calibrated?

No. The BioR can be strapped onto your vessel and will immediately begin monitoring biomass in arbitrary units (a.u.) — no calibration required.

Does the gassing rate or stirring speed influence my readings?

As an optical sensor, the CGQ BioR measures all optically active particles, including air bubbles in the bioreactor. Consequently, changing conditions—such as when running the reactor in cascadic mode—may interfere with biomass readings. This can often be minimized by adjusting the sensor position. For best results, keep the aeration rate and stirring speed as constant as possible.

Customer Success Stories

SBI-Success-Table-3

USING THE CGQ BIOR FOR THERMOPHILIC ORGANISMS

"The prolonged exposure to high temperatures was unproblematic for the CGQ BioR. Even after 400 hours of cultivation, the biomass data from the CGQ BioR was highly reliable and correlated well with OD600 and cell dry weight values. The CGQ BioR therefore seems well suited for monitoring biomass of cultivations with thermophilic organisms that require high temperatures and long fermentation times."

- Dipl. Ing. Robert Klausser, Integrated Bioprocess Development, TU Wien

tu-wien-logo-white
SBI-Success-Table-4

Using The CGQ Bior To Monitor K. Marxianus During The Production Of Ethyl Acetate

Yeasts ferment to produce ethyl acetate (EA), a widely used solvent. In this experiment, Kluyveromyces marxianus was cultivated in a synthetic medium and the CGQ BioR was used to calculate biomass-specific EA synthesis rates to identify optimal production stages.

Logo_TU_Dresden.png-1

Want To Connect The DOTS In Your Bioprocessing?